CUSTOM MARINE SERVICES The  QUICK SOURCE  For Electrical Marine Parts!

Specializing In  Circuit Breakers & Transfer Switches!

    A Yachts Best Connection!

Electrical Products Distributor...Serving The Industry Since 1973! 

 Technical Information -  3% Voltage Drop Charts 

 

Chart#3... 3% Voltage Drop @ 32 Volts

Sample Calculation= 50 A load 20 ft* from battery will require a minimum 6 gauge wire

Amps 5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300 350 400 445
Feet      
10' 18 18 16 16 14 14 12 12 10 10 10 8 8              
15' 18 16 14 14 12 12 10 10 8 8 8 6 6              
20' 18 16 12 12 12 10 10 8 8 6 6 6 6              
25' 18 14 12 12 10 10 8 8 6 6 6 6 4              
30' 16 14 10 10 10 8 8 6 6 6 4 4 4              
40' 16 12 10 10 8 8 6 6 4 4 4 2 2              
50' 14 12 8 8 8 6 6 4 4 2 2 2 2              
60' 14 10 8 8 6 6 4 4 2 2 2 2 1              
70' 12 10 6 6 6 6 4 2 2 2 1 1 1/0              
80' 12 10 6 6 6 4 4 2 2 1 1 1/0 1/0              
90' 12 8 6 6 6 4 2 2 2 1 1/0 1/0 2/0              
100' 12 8 6 6 4 4 2 2 1 1/0 1/0 2/0 2/0              
110'  10 8 6 6 4 4 2 2 1 1/0 1/0 2/0 2/0              
120'  10 8 6 4 4 2 2 1 1/0 1/0 2/0 2/0 3/0              
130'  10 8 6 4 4 2 2 1 1/0 2/0 2/0 3/0 3/0              
140' 10 6 6 4 2 2 1 1/0 1/0 2/0 3/0 3/0 3/0              
150' 10 6 6 4 2 1 1 1/0 2/0 2/0 3/0 3/0 4/0              
160' 10 6 4 4 2 1 1 1/0 2/0 3/0 3/0 4/0 4/0              
170'  8 6 4 2 2 1 1 1/0 2/0 3/0 3/0 4/0 4/0              
180'                                        
190'                                        
200'                                        
Amps 5 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300 350 400 445
*  From Battery To Load & Back to Battery

Previous Page

 

 

Home  About CMS  Products  Manufacturers 

  Contact CMS  |  Price & Del Ck  O/L Ordering | Policy  |  Privacy  Projects  Site Map

 

 Revised:12/29/2008 06:55:45